The Galt Electric G500 VFD (Model G540-00450UL-03) is a high-powered 30 HP, 480V Variable Frequency Drive designed to meet the needs of industrial-grade applications with three-phase input and output. Capable of handling both constant and variable torque applications, this VFD is ideal for heavy-duty equipment, including industrial fans, compressors, and pumps. Rated for 45A at 120% overload and 38A at 150% overload, this drive ensures flexibility and reliable performance under high demand. Built with a compact, IP20-rated enclosure and backed by a 3-year warranty, the G540-00450UL-03 operates efficiently in ambient temperatures up to 40°C, making it an ideal choice for demanding industrial environments."
-
Features and Benefits:
- Horsepower: Rated for 30 HP at 120% overload and 25 HP at 150% overload, supporting large industrial applications.
- Voltage Compatibility: 480V input and 460V output for seamless integration with high-power motor systems.
- Torque Flexibility: Compatible with both constant and variable torque applications, offering versatility across industrial environments.
- Three-Phase Power: Designed for three-phase input and output in high-demand settings.
- Enclosure: IP20-rated for secure indoor installations in controlled environments.
Product Specifications
Product Specifications
The Galt Electric G500 VFD (G540-00450UL-03) is a 30 HP, 480V AC drive with three-phase input and output, offering both constant and variable torque capabilities. It provides 45A at 120% overload and 38A at 150% overload, making it ideal for applications requiring high power and reliability in controlled indoor environments.
Applications and Uses
Applications and Uses
This VFD is suitable for large industrial applications, such as pumps, compressors, fans, and HVAC systems requiring high horsepower and precise motor control. The G500 series is engineered to handle environments where both constant and variable torque applications are needed, making it adaptable for varying load demands.
Key Features and Benefits
Key Features and Benefits
High Horsepower Capacity: Supports up to 30 HP at 120% overload and 25 HP at 150% overload for industrial applications.
Flexible Torque Control: Compatible with both constant and variable torque applications.
480V Three-Phase Input/Output: Ideal for industrial-grade, high-power motor setups.
Robust Construction: Operates efficiently in ambient temperatures up to 40°C with an IP20 enclosure.
Extended Warranty: Comes with a 3-year warranty for reliable performance and peace of mind.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Install the G500 VFD in a well-ventilated, indoor environment suited to the IP20 enclosure rating. Ensure the ambient temperature does not exceed 40°C for optimal performance. Follow grounding and installation guidelines provided in the user manual. Perform maintenance checks every 6 months, inspecting connections and removing dust buildup, and conduct a full diagnostic annually.
Warranty and Support
Warranty and Support
The Galt Electric G500 VFD includes a 3-year warranty, covering any manufacturing defects. Denver Electric Motor Depot offers support for installation, troubleshooting, and maintenance inquiries, ensuring smooth and reliable operation.
In-Depth Product Information and Specifications for Galt Electric G500 VFD - 30 HP, 480V, 3-Phase Input/Output | Model G540-00450UL-03
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Specification | Value | ||
---|---|---|---|
Horsepower (HP) | 30 HP (120% OL), 25 HP (150% OL) | ||
Input Voltage | 480V | ||
Output Voltage | 460V | ||
Rated Amps | 45 A (120% OL), 38 A (150% OL) | ||
Phase Input/Output | 3 Phase | ||
Enclosure Rating | IP 20 | ||
Ambient Temperature | Ambient Temperature Rating | 40 °C |
Maintenance Schedule and Requirements
Check all electrical connections for tightness and signs of wear to ensure safe, consistent performance.
Remove any dust buildup from the VFD's vents and surfaces to ensure proper airflow and cooling.
Run a full diagnostic test to ensure optimal performance, and check for any unusual sounds or vibrations that may indicate wear.
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.