Galt Electric GPT2000-4-447T-K Motor - 200 HP, 1800 RPM, 3-Phase, TEFC, 447T Frame
Galt Electric GPT2000-4-447T-K Motor - 200 HP, 1800 RPM, 3-Phase, TEFC, 447T Frame
Maximize your industrial operations with the high-performance Galt Electric GPT2000-4-447T-K Motor, designed to deliver 200 HP at 1800 RPM. Engineered for demanding applications, this powerful motor operates on a 3-phase, 60 Hz system with a dedicated 460V input, ensuring compatibility with heavy-duty equipment setups. Built with a rugged Totally Enclosed Fan Cooled (TEFC) enclosure and cast iron construction, this motor is resilient to environmental factors, providing reliable operation in dusty or moisture-prone settings. Boasting an exceptional efficiency of 96.2% and a 1.15 service factor, the GPT2000-4-447T-K is an energy-efficient choice for continuous, high-torque applications like pumps, compressors, and industrial mixers. With features like inverter-duty insulation, oversized regreasable bearings, and a fully gasketed junction box, this motor is crafted to endure and excel under continuous operation.
Key Features:
- Power: 200 HP
- Speed: 1800 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: TEFC (Totally Enclosed Fan Cooled)
- Frame: 447T
- Voltage: 460V
- Efficiency: Premium efficiency at 96.2%
- Service Factor: 1.15
Applications: This motor is ideal for industrial systems requiring consistent, high-torque output, such as large pumps, compressors, and mixers.
Product Specifications
Product Specifications
- Model: GPT2000-4-447T-K
- Power: 200 HP
- Speed: 1800 RPM (synchronous speed 1800 RPM)
- Phase: Three Phase
- Frequency: 60 Hz
- Frame Size: 445/7T, 445T, 447T
- Motor Enclosure Type: Totally Enclosed Fan Cooled (TEFC)
- Voltage: 460V
- Efficiency: 96.2%
- Service Factor: 1.15
- Full Load Torque: 590.25 lb-ft
- Power Factor: 0.87
- Insulation Class: F (Inverter Duty with VPI)
- Ambient Temperature Rating: 40°C
- Duty Cycle: Continuous
- Rated Amps: 223 A
- Construction: Cast Iron
- Special Features: Fully gasketed junction box, oversized regreasable bearings, stainless steel nameplate, 90° increment rotatable, AISI 4140 shaft material
Applications and Uses
Applications and Uses
Industrial Applications: Suitable for environments demanding high-torque and dependable operation, including:
- Large Pumps
- Industrial Compressors
- Mixers and Blenders
Use Case: Ideal for industries like water treatment, mining, and large-scale manufacturing, where reliable, continuous power is essential.
Key Features and Benefits
Key Features and Benefits
High-Power Performance: Delivers a robust 200 HP at 1800 RPM, suitable for heavy-duty applications requiring high torque.
Energy-Efficient Design: Achieves a high efficiency rating of 96.2%, leading to reduced operational costs and minimized energy usage.
Rugged Construction: Built with a durable cast iron frame and oversized bearings, capable of withstanding tough industrial environments.
Voltage Specific: Compatible with 460V setups, ensuring strong and stable performance.
Continuous Duty: Rated for continuous, round-the-clock operation, perfect for high-demand systems.
Inverter Duty Insulation: Equipped with insulation suitable for variable frequency drives (VFDs) to allow adjustable speed control.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Standard F1 mounting with the option for F2 configuration upon request. Compatible with 460V setups.
Maintenance: Features regreasable oversized bearings that require periodic lubrication. TEFC enclosure should be routinely checked to ensure it remains clear of dust or debris for optimal airflow.
Tip: Following Galt’s installation and maintenance guidelines will help maintain the motor’s performance and uphold the warranty.
Warranty and Support
Warranty and Support
Warranty: Backed by a 3-year warranty, covering manufacturing defects.
Support: Technical support is available for installation, maintenance, and troubleshooting needs
In-Depth Product Information and Specifications for Galt Electric GPT2000-4-447T-K Motor - 200 HP, 1800 RPM, 3-Phase, TEFC, 447T Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Freq. | Details |
---|---|---|
Lubrication | Every 6 months | Grease oversized, regreasable bearings to maintain performance in continuous-duty applications. |
Insulation Resistance Test | Annually | Conduct insulation testing, especially in VFD-supported setups for high-power applications. |
Motor Alignment Check | Annually | Check alignment to prevent wear on bearings and shaft under heavy load conditions. |
Vibration Analysis | Every 6 months | Monitor for vibrations to detect potential issues in demanding applications. |
Temperature Monitoring | Periodic | Regularly monitor temperature to prevent overheating, particularly in TEFC configurations. |
Cleaning of Enclosure | Quarterly | Clean the TEFC enclosure to maintain cooling efficiency and prevent dust accumulation. |
Electrical Connections Inspection | Every 6 months | Inspect and secure all electrical connections to prevent interruptions or arcing. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.