Galt Electric GDP0010-4-143T-K ODP Motor - 1 HP, 1800 RPM, 3-Phase, 143T Frame
Galt Electric GDP0010-4-143T-K ODP Motor - 1 HP, 1800 RPM, 3-Phase, 143T Frame
Galt Electric GDP0010-4-143T-K ODP Motor delivers reliable 1 HP power at 1800 RPM, making it ideal for light to moderate-duty applications that require efficient performance in open environments. Designed for 3-phase, 60 Hz systems, this motor supports voltage options of 208V, 230V, and 460V, offering flexibility for various setups. Its Open Drip Proof (ODP) enclosure ensures air cooling, making it suitable for applications where dust and moisture are minimal. Built with a rolled steel construction, it provides a lightweight yet durable option for continuous-duty operations. This motor has an 85.5% efficiency rating and a service factor of 1.25, providing reliable, efficient performance in pumps, blowers, and light-duty machinery.
Key Features:
- Power: 1 HP
- Speed: 1800 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: ODP (Open Drip Proof)
- Frame: 143T
- Voltage: 208V, 230V, 460V
- Efficiency: 85.5%
- Service Factor: 1.25
Applications: Best suited for indoor, light-duty applications where air cooling is sufficient, such as blowers, small pumps, and general-purpose machinery
Product Specifications
Product Specifications
Model: GDP0010-4-143T-K
Power: 1 HP
Speed: 1800 RPM (synchronous speed 1800 RPM)
Phase: Three Phase
Frequency: 60 Hz
Frame Size: 143T
Motor Enclosure Type: Open Drip Proof (ODP)
Voltage: 208V, 230V, 460V
Efficiency: 85.5%
Service Factor: 1.25
Full Load Torque: 3.02 lb-ft
Power Factor: 0.71
Insulation Class: F
Ambient Temperature Rating: 40°C
Duty Cycle: Continuous
Rated Amps: 1.5 A, 3 A, 3.3 A
Construction: Rolled Steel
Special Features: Stainless steel nameplate, flexible mounting configuration, lightweight design
Applications and Uses
Applications and Uses
Industrial Applications: Suitable for indoor, open environments where air cooling is possible, including:
- Blowers and Fans
- Small Pumps
- General-Purpose Machinery
Use Case: Ideal for indoor manufacturing and processing environments, where light-duty, continuous performance is needed.
Key Features and Benefits
Key Features and Benefits
Reliable Power Output: Delivers consistent 1 HP power at 1800 RPM, suitable for light-duty industrial applications.
Flexible Voltage Compatibility: Operates on 208V, 230V, and 460V, offering versatility for different power setups.
Lightweight and Durable: Constructed from rolled steel, providing durability with a lightweight design.
Continuous Duty: Rated for continuous operation, ideal for applications that require steady, ongoing performance.
Open Drip Proof Cooling: The ODP design provides adequate air cooling for controlled environments, ensuring efficient motor performance.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Compatible with F1 mounting. Ensure compatibility with either 208V, 230V, or 460V setups.
Maintenance: As an ODP motor, routine cleaning is recommended to prevent dust buildup and maintain optimal airflow.
Tip: Adhere to Galt’s installation and maintenance instructions to ensure efficiency and warranty compliance.
Warranty and Support
Warranty and Support
Warranty: Includes a 3-year warranty covering manufacturing defects.
Support: Technical support is available for guidance on installation, maintenance, and troubleshooting.
In-Depth Product Information and Specifications for Galt Electric GDP0010-4-143T-K ODP Motor - 1 HP, 1800 RPM, 3-Phase, 143T Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Frequency | Details |
---|---|---|
Lubrication | Annually | Apply bearing grease to maintain optimal performance in continuous-duty applications. |
Insulation Resistance Test | Annually | Conduct insulation resistance testing to ensure safe and efficient operation. |
Motor Alignment Check | Annually | Verify alignment to prevent unnecessary wear on bearings and shafts. |
Vibration Analysis | Every 6 months | Monitor for vibrations that may indicate mechanical issues, especially in light-duty use. |
Temperature Monitoring | Periodic | Check motor temperature regularly to prevent overheating, especially in ODP setups. |
Cleaning of Enclosure | Every 3 months | Clean the ODP enclosure to remove dust and debris, ensuring airflow. |
Electrical Connections Inspection | Every 6 months | Inspect and secure all electrical connections to prevent power interruptions. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.