Galt Electric GPT3000-4-449T-K Motor - 300 HP, 1800 RPM, 3-Phase, TEFC, 449T Frame
Galt Electric GPT3000-4-449T-K Motor - 300 HP, 1800 RPM, 3-Phase, TEFC, 449T Frame
Galt Electric GPT3000-4-449T-K Motor brings high-power performance with a substantial 300 HP at 1800 RPM, making it a powerful choice for intense industrial applications. Designed to run on a 3-phase, 460V system at 60 Hz, this motor provides the reliable, continuous power needed for large-scale operations. With a Totally Enclosed Fan Cooled (TEFC) design and rugged cast iron construction, it’s built to withstand harsh environments, protecting against dust and moisture. This motor also boasts an impressive 96.2% efficiency and a 1.15 service factor, maximizing energy savings while delivering high torque (885.37 lb-ft) for demanding applications. Ideal for heavy-duty setups like pumps, compressors, and mixers, this motor’s inverter-duty insulation, regreasable bearings, and fully gasketed junction box add to its durability and low-maintenance operation.
Key Features:
- Power: 300 HP
- Speed: 1800 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: TEFC (Totally Enclosed Fan Cooled)
- Frame: 449T
- Voltage: 460V
- Efficiency: 96.2%
- Service Factor: 1.15
Applications: This motor is perfectly suited for high-demand industrial applications requiring continuous, high-torque output, such as large-scale pumps, compressors, and industrial mixers.
Product Specifications
Product Specifications
Model: GPT3000-4-449T-K
Power: 300 HP
Speed: 1800 RPM (synchronous speed 1800 RPM)
Phase: Three Phase
Frequency: 60 Hz
Frame Size: 447/9T, 447T, 449T
Motor Enclosure Type: Totally Enclosed Fan Cooled (TEFC)
Voltage: 460V
Efficiency: 96.2%
Service Factor: 1.15
Full Load Torque: 885.37 lb-ft
Power Factor: 0.87
Insulation Class: F (Inverter Duty with VPI)
Ambient Temperature Rating: 40°C
Duty Cycle: Continuous
Rated Amps: 335 A
Construction: Cast Iron
Special Features: Fully gasketed junction box, oversized regreasable bearings, stainless steel nameplate, 90° increment rotatable, AISI 4140 shaft material
Applications and Uses
Applications and Uses
Industrial Applications: Suitable for high-demand settings requiring robust power and reliability, including:
- Large-Scale Pumps
- Heavy-Duty Compressors
- Industrial Mixers and Blenders
Key Features and Benefits
Key Features and Benefits
High-Torque Performance: Offers a powerful 885.37 lb-ft of torque at 1800 RPM, ideal for heavy-duty applications.
Energy Efficient: Operates with a premium efficiency of 96.2%, delivering savings in energy costs over time.
Rugged Construction: Built with durable cast iron and oversized bearings, designed for continuous operation in harsh industrial settings.
Voltage Specific: Optimized for 460V systems, ensuring stable performance in demanding applications.
Continuous Duty: Rated for continuous operation, suitable for 24/7 usage in industrial environments.
Inverter Duty Insulation: Equipped with VPI-treated insulation, enabling compatibility with VFDs for flexible speed control.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Standard F1 mounting configuration with an option for F2 upon request. Compatible with 460V setups.
Maintenance: Features regreasable oversized bearings, requiring periodic lubrication for sustained performance. Keep the TEFC enclosure clear of dust for optimal airflow.
Tip: Follow Galt’s guidelines to maximize motor efficiency and ensure compliance with warranty requirements.
Warranty and Support
Warranty and Support
Warranty: Includes a 3-year warranty for manufacturing defects.
Support: Comprehensive technical support is available to assist with installation, maintenance, and troubleshooting.
In-Depth Product Information and Specifications for Galt Electric GPT3000-4-449T-K Motor - 300 HP, 1800 RPM, 3-Phase, TEFC, 449T Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Freq. | Details |
---|---|---|
Lubrication | Every 6 months | Grease oversized, regreasable bearings for consistent performance in continuous-duty applications. |
Insulation Resistance Test | Annually | Perform insulation testing, especially if the motor is used with variable frequency drives (VFDs). |
Motor Alignment Check | Annually | Verify alignment to reduce wear on bearings and shaft in high-RPM settings. |
Vibration Analysis | Every 6 months | Monitor for excessive vibrations to detect potential mechanical issues in high-speed operations. |
Temperature Monitoring | Periodic | Regularly monitor motor temperature to prevent overheating in TEFC environments. |
Cleaning of Enclosure | Quarterly | Clean the TEFC enclosure to maintain cooling efficiency and prevent dust buildup. |
Electrical Connections Inspection | Every 6 months | Inspect and secure electrical connections to avoid interruptions or arcing. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.