Galt Electric GPT0400-6-364T-K Motor - 40 HP, 1200 RPM, 3-Phase, TEFC, 364T Frame
Galt Electric GPT0400-6-364T-K Motor - 40 HP, 1200 RPM, 3-Phase, TEFC, 364T Frame
Built for demanding industrial applications, the Galt Electric GPT0400-6-364T-K Motor provides 40 HP at 1200 RPM, delivering consistent high-torque performance. This motor is compatible with 3-phase, 60 Hz systems and supports 230V and 460V configurations, allowing for versatile installations. Constructed with a Totally Enclosed Fan Cooled (TEFC) design and cast iron housing, it is designed to operate reliably in challenging environments, protecting against dust, moisture, and debris. With an impressive efficiency rating of 94.1% and a 1.25 service factor, this motor is ideal for applications like mixers, crushers, and heavy-duty pumps. Additional features include oversized, regreasable bearings, inverter-duty insulation, and a fully gasketed junction box, providing durability and reliability for continuous operation.
Key Features:
- Power: 40 HP
- Speed: 1200 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: TEFC (Totally Enclosed Fan Cooled)
- Frame: 364T
- Voltage: 230V / 460V
- Efficiency: Premium efficiency at 94.1%
- Service Factor: 1.25
Applications: Ideal for industrial tasks that require high torque at lower speeds, such as mixers, crushers, and heavy-duty pumps in continuous operation environments.
Product Specifications
Product Specifications
- Model: GPT0400-6-364T-K
- Power: 40 HP
- Speed: 1200 RPM (synchronous speed 1200 RPM)
- Phase: Three Phase
- Frequency: 60 Hz
- Frame Size: 364T
- Motor Enclosure Type: Totally Enclosed Fan Cooled (TEFC)
- Voltage: 230V / 460V
- Efficiency: 94.1%
- Service Factor: 1.25
- Full Load Torque: 178.08 lb-ft
- Power Factor: 0.78
- Insulation Class: F (Inverter Duty with VPI)
- Ambient Temperature Rating: 40°C
- Duty Cycle: Continuous
- Rated Amps: 51 A (230V), 102 A (460V)
- Construction: Cast Iron
- Special Features: Fully gasketed junction box, oversized regreasable bearings, stainless steel nameplate, 90° increment rotatable, AISI 4140 shaft material
Applications and Uses
Applications and Uses
Industrial Applications: Ideal for low-speed, high-torque applications in tough environments, including:
- Mixers
- Crushers
- Heavy-Duty Pumps
Use Case: Suitable for industries like chemical processing, mining, and material handling, where reliable, continuous operation is critical.
Key Features and Benefits
Key Features and Benefits
High-Torque Performance: Provides 178.08 lb-ft of torque at 1200 RPM, ideal for heavy-duty applications requiring robust power.
Exceptional Efficiency: Operates with an efficiency rating of 94.1%, reducing energy costs over time.
Durable Construction: Made from rugged cast iron with sealed bearings to handle harsh industrial conditions.
Flexible Voltage: Works with both 230V and 460V, providing flexibility for diverse installations.
Continuous Duty: Rated for continuous operation, making it suitable for round-the-clock applications.
Inverter Duty Insulation: Includes VPI-treated insulation, ensuring compatibility with variable frequency drives (VFDs) for variable speed control.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Standard F1 mounting with F2 configuration available upon request. Ensure compatibility with either 230V or 460V systems.
Maintenance: This motor features regreasable oversized bearings for ease of maintenance. Regular dusting and lubrication are recommended for optimal performance.
Tip: Follow Galt’s installation guidelines to ensure longevity and warranty compliance.
Warranty and Support
Warranty and Support
Warranty: Comes with a 3-year warranty, covering against manufacturing defects.
Support: Full technical support is available for installation, maintenance, and troubleshooting.
In-Depth Product Information and Specifications for Galt Electric GPT0400-6-364T-K Motor - 40 HP, 1200 RPM, 3-Phase, TEFC, 364T Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Freq. | Details |
---|---|---|
Lubrication | Every 6 months | Grease oversized, regreasable bearings for optimal performance in heavy-duty applications. |
Insulation Resistance Test | Annually | Conduct insulation testing, especially in applications with variable frequency drives (VFDs). |
Motor Alignment Check | Annually | Verify alignment to prevent wear on bearings and shaft for continuous-duty setups. |
Vibration Analysis | Every 6 months | Monitor for excessive vibrations to detect potential issues in high-torque operations. |
Temperature Monitoring | Periodic | Regularly monitor motor temperature to avoid overheating in TEFC environments. |
Cleaning of Enclosure | Quarterly | Clean the TEFC enclosure to maintain airflow and prevent dust buildup. |
Electrical Connections Inspection | Every 6 months | Inspect and secure electrical connections to prevent power interruptions or arcing. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.