Galt Electric GPT0500-2-326TS-K Motor - 50 HP, 3600 RPM, 3-Phase, TEFC, 326TS Frame
Galt Electric GPT0500-2-326TS-K Motor - 50 HP, 3600 RPM, 3-Phase, TEFC, 326TS Frame
The Galt Electric GPT0500-2-326TS-K Motor offers an impressive 50 HP at 3600 RPM, designed for applications where high-speed, powerful performance is essential. This 3-phase motor operates at 60 Hz and supports both 230V and 460V systems, making it versatile for various installations. Featuring a Totally Enclosed Fan Cooled (TEFC) enclosure, it’s well-suited for industrial environments where protection from dust and moisture is critical. With an efficiency rating above 93% and a 1.25 service factor, this motor is optimized for continuous operation in high-demand applications, such as compressors, fans, and pumps. Additional features include inverter-duty insulation, oversized regreasable bearings, and a fully gasketed junction box, providing durability and longevity.
Key Features:
- Power: 50 HP
- Speed: 3600 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: TEFC (Totally Enclosed Fan Cooled)
- Frame: 326TS
- Voltage: 230V / 460V
- Efficiency: Premium efficiency at over 93%
- Service Factor: 1.25
Applications: Suitable for high-speed applications like industrial compressors, pumps, and fans, where consistent and powerful performance is required.
Product Specifications
Product Specifications
Model: GPT0500-2-326TS-K
Power: 50 HP
Speed: 3600 RPM (synchronous speed 3600 RPM)
Phase: Three Phase
Frequency: 60 Hz
Frame Size: 324/6TS, 324TS, 326TS
Motor Enclosure Type: Totally Enclosed Fan Cooled (TEFC)
Voltage: 230V / 460V
Efficiency: 93%
Service Factor: 1.25
Full Load Torque: Calculated based on power and speed
Power Factor: 0.86
Insulation Class: F (Inverter Duty with VPI)
Ambient Temperature Rating: 40°C
Duty Cycle: Continuous
Rated Amps: 51 A (230V), 102 A (460V)
Construction: Cast Iron
Special Features: Fully gasketed junction box, oversized regreasable bearings, stainless steel nameplate, 90° increment rotatable, AISI 4140 shaft material
Applications and Uses
Applications and Uses
Industrial Applications: Perfect for high-speed applications in demanding environments, including:
- Compressors
- Industrial Fans
- Pumps
Use Case: Well-suited for industries such as manufacturing, HVAC, and water treatment, where reliable high-speed motors are essential.
Key Features and Benefits
Key Features and Benefits
High-Speed Performance: Delivers 50 HP at 3600 RPM, ideal for applications requiring fast, powerful output.
Premium Efficiency: Operates at over 93% efficiency, helping reduce energy costs in continuous-use applications.
Durable Construction: Cast iron build with oversized, sealed bearings designed for heavy-duty environments.
Voltage Flexibility: Compatible with both 230V and 460V, suitable for diverse industrial setups.
Continuous Duty: Rated for continuous operation, making it ideal for applications that demand consistent, long-term power.
Inverter Duty Insulation: Equipped with VPI-treated insulation, supporting use with variable frequency drives (VFDs) for speed control.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Standard F1 mounting with an F2 option available upon request. Confirm compatibility with 230V or 460V power systems.
Maintenance: Features regreasable oversized bearings for simplified maintenance. Routine cleaning of the TEFC enclosure and lubrication of bearings are recommended.
Tip: Follow Galt’s installation and maintenance guidelines to optimize motor performance and ensure warranty validity.
Warranty and Support
Warranty and Support
Warranty: Includes a 3-year warranty, covering manufacturing defects.
Support: Comprehensive technical support available for installation, troubleshooting, and maintenance.
In-Depth Product Information and Specifications for Galt Electric GPT0500-2-326TS-K Motor - 50 HP, 3600 RPM, 3-Phase, TEFC, 326TS Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Freq. | Details |
---|---|---|
Lubrication | Every 6 months | Grease oversized, regreasable bearings for smooth, reliable operation in continuous-duty applications. |
Insulation Resistance Test | Annually | Perform insulation testing, particularly if used with variable frequency drives (VFDs). |
Motor Alignment Check | Annually | Inspect alignment to reduce wear on bearings and shaft, especially in high-RPM settings. |
Vibration Analysis | Every 6 months | Monitor for excessive vibrations that may indicate potential mechanical issues in high-speed operations. |
Temperature Monitoring | Periodic | Regularly monitor temperature to prevent overheating in TEFC configurations. |
Cleaning of Enclosure | Quarterly | Clean the TEFC enclosure to maintain efficient cooling and prevent dust accumulation. |
Electrical Connections Inspection | Every 6 months | Inspect and secure electrical connections to avoid interruptions or arcing. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.