Galt Electric GPT0600-4-364T-K Motor - 60 HP, 1800 RPM, 3-Phase, TEFC, 364T Frame
Galt Electric GPT0600-4-364T-K Motor - 60 HP, 1800 RPM, 3-Phase, TEFC, 364T Frame
Galt Electric GPT0600-4-364T-K Motor delivers robust power with a 60 HP output at 1800 RPM, designed for demanding industrial applications. This motor is compatible with 3-phase, 60 Hz systems, supporting both 230V and 460V setups for versatile installation options. Built with a Totally Enclosed Fan Cooled (TEFC) design and a durable cast iron frame, it provides excellent protection against dust, moisture, and other environmental factors, making it suitable for heavy-duty environments. With a premium efficiency rating of 95% and a 1.25 service factor, this motor is engineered for energy-saving, continuous operation in applications like conveyors, pumps, and compressors. Additional features include inverter-duty insulation, regreasable oversized bearings, and a fully gasketed junction box to ensure long-lasting performance.
Key Features:
- Power: 60 HP
- Speed: 1800 RPM
- Phase: 3-Phase
- Frequency: 60 Hz
- Enclosure: TEFC (Totally Enclosed Fan Cooled)
- Frame: 364T
- Voltage: 230V / 460V
- Efficiency: Premium efficiency at 95%
- Service Factor: 1.25
Applications: Ideal for high-demand applications such as industrial conveyors, compressors, and heavy-duty pumps, where continuous high-torque performance is essential.
Product Specifications
Product Specifications
- Model: GPT0600-4-364T-K
- Power: 60 HP
- Speed: 1800 RPM (synchronous speed 1800 RPM)
- Phase: Three Phase
- Frequency: 60 Hz
- Frame Size: 364T
- Motor Enclosure Type: Totally Enclosed Fan Cooled (TEFC)
- Voltage: 230V / 460V
- Efficiency: 95%
- Service Factor: 1.25
- Full Load Torque: 177.55 lb-ft
- Power Factor: 0.85
- Insulation Class: F (Inverter Duty with VPI)
- Ambient Temperature Rating: 40°C
- Duty Cycle: Continuous
- Rated Amps: 69 A (230V), 138 A (460V)
- Construction: Cast Iron
- Special Features: Fully gasketed junction box, oversized regreasable bearings, stainless steel nameplate, 90° increment rotatable, AISI 4140 shaft material
Applications and Uses
Applications and Uses
Industrial Applications: Ideal for applications requiring continuous high-torque and reliability, including:
- Conveyors
- Compressors
- Heavy-Duty Pumps
Use Case: Perfect for industries such as manufacturing, water treatment, and material handling, where dependable and continuous operation is required.
Key Features and Benefits
Key Features and Benefits
High-Torque Performance: Provides 177.55 lb-ft of torque at 1800 RPM, ideal for demanding applications.
Energy Efficient: Operates at 95% efficiency, helping to reduce energy costs in high-usage applications.
Rugged Construction: Cast iron build with oversized, sealed bearings, designed for harsh industrial conditions.
Voltage Flexibility: Compatible with both 230V and 460V, allowing for flexible installation across various setups.
Continuous Duty: Rated for continuous operation, suitable for applications that require round-the-clock performance.
Inverter Duty Insulation: Comes with VPI-treated insulation, enabling use with variable frequency drives (VFDs) for flexible speed control.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Installation: Standard F1 mounting with optional F2 configuration upon request. Ensure compatibility with 230V or 460V power sources.
Maintenance: Equipped with regreasable oversized bearings, which require periodic lubrication. Routine cleaning of the TEFC enclosure is recommended to maintain efficiency.
Tip: Follow Galt’s installation and maintenance guidelines to maximize the motor’s lifespan and ensure warranty coverage.
Warranty and Support
Warranty and Support
Warranty: Covered by a 3-year warranty, protecting against manufacturing defects.
Support: Technical support available for installation, troubleshooting, and ongoing maintenance assistance.
In-Depth Product Information and Specifications for Galt Electric GPT0600-4-364T-K Motor - 60 HP, 1800 RPM, 3-Phase, TEFC, 364T Frame
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Maintenance Schedule and Requirements
Task | Freq. | Details |
---|---|---|
Lubrication | Every 6 months | Grease oversized, regreasable bearings to ensure smooth operation in continuous-duty settings. |
Insulation Resistance Test | Annually | Conduct insulation testing, especially when using inverter duty for VFD applications. |
Motor Alignment Check | Annually | Check alignment to prevent wear on bearings and shaft, especially in heavy-duty applications. |
Vibration Analysis | Every 6 months | Monitor for vibrations to detect potential issues early in demanding environments. |
Temperature Monitoring | Periodic | Regularly check motor temperature to avoid overheating, particularly in TEFC configurations. |
Cleaning of Enclosure | Quarterly | Clean the TEFC enclosure to maintain cooling efficiency and prevent dust buildup. |
Electrical Connections Inspection | Every 6 months | Inspect and secure electrical connections to prevent power interruptions or arcing. |
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.