Mitsubishi F840 VFD - 3 HP, 460V, 3-Phase Input/Output | Model FR-F840-00052-3-N6
Mitsubishi F840 VFD - 3 HP, 460V, 3-Phase Input/Output | Model FR-F840-00052-3-N6
The Mitsubishi F840 VFD (Model FR-F840-00052-3-N6) is a reliable 3 HP, 460V Variable Frequency Drive designed for industrial variable torque applications. Rated for 5.2A at 460V, this VFD delivers precise motor control for pumps, fans, and HVAC systems. With support for advanced communication protocols like Modbus TCP/IP and CC-Link IE, it ensures seamless system integration. Featuring a UL Type 1 enclosure, this VFD is suitable for safe indoor installations. Mitsubishi’s F800 series is known for its durability, energy efficiency, and high-performance motor control.
Features and Benefits:
- Horsepower: 3 HP with 110% and 120% overload capacities for diverse applications.
- Voltage Compatibility: 460V input/output for industrial motor systems.
- Variable Torque: Optimized for fluctuating load applications such as pumps and fans.
- Three-Phase Input/Output: Ensures stable and efficient power delivery.
- Advanced Communication: Includes Modbus TCP/IP and CC-Link IE for enhanced connectivity.
Product Specifications
Product Specifications
The Mitsubishi F840 VFD (FR-F840-00052-3-N6) is a versatile 3 HP, 460V AC drive engineered for energy-efficient motor control and precise performance in industrial systems.
Applications and Uses
Applications and Uses
Ideal for variable torque applications such as pumps, fans, and HVAC systems, this VFD ensures reliable and energy-efficient motor control in industrial and commercial settings.
Key Features and Benefits
Key Features and Benefits
3 HP Capacity: Handles light-to-medium-duty applications with overload protection for reliability.
Variable Torque: Perfect for applications with fluctuating load demands, maximizing energy savings.
Advanced Communication Protocols: Modbus TCP/IP and CC-Link IE ensure seamless integration with modern systems.
Durable UL Type 1 Enclosure: Provides safe and secure indoor installations.
Energy Efficiency: Reduces power consumption and operational costs.
Installation and Maintenance Guidelines
Installation and Maintenance Guidelines
Install the F840 VFD in a ventilated indoor location compliant with UL Type 1 standards. Ensure proper grounding and wiring as per the user manual. Routine maintenance includes inspecting connections and clearing dust every 6 months, with an annual diagnostic check for optimal performance.
Warranty and Support
Warranty and Support
The Mitsubishi F840 VFD includes comprehensive support for installation, troubleshooting, and maintenance. Mitsubishi ensures quality with a robust warranty.
In-Depth Product Information and Specifications for Mitsubishi F840 VFD - 3 HP, 460V, 3-Phase Input/Output | Model FR-F840-00052-3-N6
Efficiency Comparison Chart
Applications and Recommended Use Cases
Energy Cost Savings Over Time
Technical Specifications Breakdown
Specification | Value |
---|---|
Horsepower (HP) | 3 HP |
Input Voltage | 460V |
Output Voltage | 460V |
Rated Amps | 4.8 A (120% OL), 5.2 A (110% OL) |
Output Amperage | 5.2 A |
Phase Input/Output | 3 Phase |
Torque Type | Variable Torque |
Enclosure Rating | UL Type 1 |
Series | F800 |
Weight | 3.63 lbs |
Maintenance Schedule and Requirements
Check all electrical connections for tightness and inspect for wear to ensure safe, continuous operation.
Remove dust buildup from vents and surfaces to maintain optimal airflow and cooling efficiency.
Conduct a full diagnostic test to ensure optimal performance. Check for unusual sounds or vibrations indicating potential issues.
Resources
View all-
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
The Ultimate Guide to 30HP Electric Motors: App...
A 30HP electric motor is a versatile solution for heavy-duty applications across industrial, commercial, and agricultural sectors. Whether you're replacing a motor in existing equipment or seeking a new, energy-efficient...
-
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
Understanding Motor Requirements in Food & Beve...
Struggling with motor selection for your food processing facility? This comprehensive guide breaks down everything from washdown requirements to regulatory compliance. Learn which motors you need, why you need them,...
-
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.
Electric Motor Safety: Essential Protocols for ...
A practical guide covering safety measures when working with and maintaining electric motors, which complements many existing posts regarding motor efficiency and maintenance.